With its simple operation, compact design and ease of use, the Fluke 115 True RMS digital multimeter provides the perfect answer for general purpose electrical and electronic test requirements. The Fluke 115 displays True RMS voltage and current readings with 600 count resolution, continuity and capacitance, making it perfect for quick verifications and field service use. Fluke 115 Digital Multimeters are independently tested for safe use in CAT III 600V Environments. How much is Fluke 115 True RMS Multimeter price?
Key features
- Large white LED backlight to work in poorly lit areas
- Compact ergonomic design for one-handed operation
- Compatible with optional magnetic hanger (ToolPak)
- True-rms for accurate measurements on non-linear loads
- Resistance, continuity, frequency, capacitance, and diode test
- Measures 20 A (30 seconds momentary; 10 A continuous)
- Min/Max/Average with elapsed time to record signal fluctuations
- CAT III 600 V safety rated
- True RMS
- .5% Accuracy
- 28% larger digits
Specifications – Fluke 115 True RMS Multimeter
DC Millivolts | |
Range | 600 mV |
Resolution | 0.1 mV |
Accuracy | 0.5% + 2 |
DC Volts | |
Range | 6 V 60 V 600 V |
Resolution | 0.001 V 0.01 V 0.1 V |
Accuracy | 0.5% + 2 |
Auto Volts | |
Range | 600 V |
Resolution | 0.1 V |
Accuracy | 2.0% + 3 (dc 45 to 500 Hz) 4.0% + 3 (500 Hz to 1kHz) |
AC Millivolts1 True RMS | |
Range | 600 mV |
Resolution | 0.1 mV |
Accuracy | 1.0% + 3 (dc 45 to 500 Hz) 2.0% + 3 (500 Hz to 1kHz) |
AC Volts1 True RMS | |
Range | 6 V 60 V 600 V |
Resolution | 0.001 V 0.01 V 0.1 V |
Accuracy | 1.0% + 3 (dc 45 to 500 Hz) 2.0% + 3 (500 Hz to 1kHz) |
Continuity | |
Range | 600 Ω |
Resolution | 1 Ω |
Accuracy | Beeper on <20 off> 250; detects opens or shorts of 500 µs or longer |
Ohms | |
Range | 600 Ω 6 kΩ 60 kΩ 600 kΩ 6 MΩ 40 MΩ |
Resolution | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.001 MΩ 0.01 MΩ |
Accuracy | 0.9% + 2 0.9% + 1 5% + 2 |
Diode Test | |
Range | 2 V |
Resolution | 0.001 V |
Accuracy | 0.9% + 2 |
Capacitance | |
Range | 1000 nF 10 µF 100 µF 9999 µF 100 to 1000 µF >1000 µF |
Resolution | 1 nF 0.01 µF 0.1 µF 1 µF |
Accuracy | 1.9% + 2 1.9% + 2 5% + 20 |
Lo-Z capacitance | |
Range | 1 nF to 500 µF |
Accuracy | 10% + 2 typical |
AC Amps True RMS (45 to 500 Hz) | |
Range | 6 A 10 A 20 A overload for 30 seconds max |
Resolution | 0.001 A 0.01 A |
Accuracy | 1.5% + 3 |
DC Amps | |
Range | 6 A 10 A 20 A overload for 30 seconds max |
Resolution | 0.001 A 0.01 A |
Accuracy | 1.0% + 3 |
Hz (V or A Input)2 | |
Range | 99.99 Hz 999.9 Hz 9.999 kHz 50.00 kHz |
Resolution | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz |
Accuracy | 0.1% + 2 |
Compare Fluke 115 True RMS Multimeter price
Fluke 115 | Fluke 117 | Fluke 87-V | |
---|---|---|---|
Tests | Resistance, continuity, frequency and capacitance | Resistance, continuity, frequency and capacitance | Resistance, continuity and diode test |
True RMS | ✓ | ✓ | ✓ |
LED Backlight | ✓ | ✓ | ✓ |
Min/Max Recording | ✓ | ✓ | ✓ |
Safety Ratings | CAT III 600 V safety rated | CAT III 600 V safety rated | CAT III 600 V safety rated |
Features | 10A ac/dc current measurement (20 A overload for 30-seconds max) | VoltAlert technology for non-contact voltage detection | Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument |
Maximum Voltage ac/dc 600V | AutoVolt automatic AC/DC voltage selection | Measure up to 1000 VAC and DC | |
Low input impedance: helps prevent false readings due to ghost voltage | Measure up to 10 A, 20 A for up to 30 seconds |